Decision guide in Leaks, freezes and sensors
Water leak detector with automatic shut off valve in Vancouver, BC: what each setup does
In a Vancouver, BC home, a water leak detector with automatic shut off valve closes the main water inlet when a sensor finds water; a detector alone only alarms. Sinopé's Wi-Fi kit pairs five detectors with the valve and a backup battery for up to 24 hours, and one valve can work with up to 20 detectors.
By the Saturn Home Automation team Updated
How the three leak detector setups compare
The table below sets out the three setups row by row, and the difference is one thing: who stops the water.
A detector alone is an alarm. A detector with a hub or gateway adds alerts to a phone. Neither closes a valve. A detector with an automatic shut-off valve signals the valve, which closes the main water inlet. With Sinopé’s detector, every setup senses water from the same depth, 0.4 mm.
The table uses Sinopé’s pages for both configurations as one maker’s example. Ask which brands Saturn installs when you book. Saturn offers water leak detection with automatic water shut-off for kitchens, bathrooms and basements among its services. The sensors and leak detection service is where the sensors, alerts and automations are planned.
Choosing between leak alerts and automatic shut-off?
| Detector alone | Detector with hub or gateway | Detector with shut-off valve | |
|---|---|---|---|
| What happens when water reaches the sensor | An audible alarm sounds | Notifications are sent; Sinopé's detector sends them only when connected to a Sedna valve or a Sinopé gateway | The detector signals the valve, which closes the main water inlet and sends an email or push alert naming the location |
| What stops the water | A person, after hearing the alarm | A person, after reading the alert | The valve, automatically |
| How little water it senses | From 0.4 mm (0.015 in) deep | From 0.4 mm (0.015 in) deep | From 0.4 mm (0.015 in) deep |
| Leaks you cannot see | Only where a detector sits | Only where a detector sits | An optional flow sensor on the valve flags abnormal flow of 2 L/min (3/4 inch) or 4 L/min (1 inch), for broken pipes inside walls and ceilings |
| During an internet outage | The audible alarm still sounds on the detector | Check the gateway's spec | The valve still closes; alerts need a permanent internet connection |
| During a power cut | The detector runs on two AAA batteries | Sinopé warns the signal between the detector and its Zigbee gateway is not possible in a power outage | The Wi-Fi kit has a rechargeable backup battery for up to 24 hours of protection |
| How many detectors one system takes | Each detector alarms on its own | Check the gateway's spec | Up to 20 per valve; the kit includes five |
| Where the maker says to put them | Near the water heater, trash pump, refrigerator, sinks, toilets, water softener, bathtub, dishwasher and washing machine | The same locations | The same locations |
| Strata deductible if the loss is on the strata's policy | A common expense paid through strata fees; the strata may sue an owner who is responsible for the loss | The same rule | The same rule |
| A deductible in one tribunal case | $25,000, removed by the tribunal because negligence was not proven | The same case | The same case |
When a detector with alerts is enough
A detector with alerts is enough when someone can reach the water supply within minutes of the alert.
That fits a home where people are in and out all day and a leak would be caught under a sink or beside the washing machine. Alerts reach your phone, and you close the valve you already have. A detector sends notifications only when it is connected to a valve or a gateway. Without either, you get the audible alarm and nothing more.
Alerts have limits the table shows. Sinopé’s alerts need a permanent internet connection. The detector senses water only where it sits, so a pipe leaking inside a wall is invisible to it.
When an automatic shut-off valve earns its place
An automatic shut-off valve earns its place when nobody is there to act: an empty suite, a second home, a week away.
Saturn offers leak detection for vacant or seasonal properties too. In those homes an alert at 2 a.m. does nothing until someone reads it. The valve closes the inlet without being asked, and it still closes without internet. One valve can work with up to 20 detectors, so a whole home is one system.
Two cautions come from the maker. In a power outage a Zigbee gateway cannot pass a detector’s signal, and Sinopé recommends its Wi-Fi kit with backup instead. That backup lasts up to 24 hours, not longer. For leaks inside walls and ceilings, the optional flow sensor flags abnormal flow of 2 L/min or 4 L/min, depending on the pipe size.
A shut-off valve sits on the water supply. Ask who fits it before you commit, because that is separate from choosing the sensors.
Where to put the detectors
Put a detector wherever water would appear first: appliances, fixtures and anything that holds water.
Sinopé’s list is the water heater, trash pump, refrigerator, sinks, toilets, water softener, bathtub, dishwasher and washing machine. The same page adds areas prone to freezing: a wine cellar, piping, an unattended cottage or second home. The frozen pipe guide covers the freeze side for Vancouver.
What a strata deductible adds to the stakes
In a BC strata, a water leak can turn into a deductible charge, which raises the cost of a slow response.
Under the Strata Property Act, a deductible on a claim on the strata’s insurance is a common expense paid through strata fees. The strata may sue an owner who is responsible for the loss to recover it. In one tribunal case the deductible was $25,000. The tribunal removed the charge because that strata’s bylaws required negligence and it was not proven. It is one strata’s bylaws, not the general rule. The strata deductible guide sets out who pays, case by case.
The service behind this guide
Questions people ask
Do water leak detectors shut off the water?
Not by themselves. A Sinopé detector on its own sounds an audible alarm, and it sends notifications only when connected to a Sedna valve or a Sinopé gateway. The shut-off comes from a valve: the detector signals it and it closes the main water inlet.
Does a leak shut-off valve work when the power is out?
It depends on the setup. Sinopé's Wi-Fi Sedna kit includes a rechargeable backup battery for up to 24 hours of protection. Sinopé warns that its Zigbee gateway cannot pass a detector's signal during a power outage, so a Zigbee valve would not get the closing signal.
Where should water leak sensors go?
Sinopé recommends them near the water heater, trash pump, refrigerator, sinks, toilets, water softener, bathtub, dishwasher and washing machine. It also names areas prone to freezing: a wine cellar, piping, or an unattended cottage or second home.